Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
JAMA Netw Open ; 6(4): e239694, 2023 04 03.
Article in English | MEDLINE | ID: covidwho-2291176

ABSTRACT

Importance: Evidence on the effectiveness and safety of COVID-19 therapies across a diverse population with varied risk factors is needed to inform clinical practice. Objective: To assess the safety of neutralizing monoclonal antibodies (nMAbs) for the treatment of COVID-19 and their association with adverse outcomes. Design, Setting, and Participants: This retrospective cohort study included 167 183 patients from a consortium of 4 health care systems based in California, Minnesota, Texas, and Utah. The study included nonhospitalized patients 12 years and older with a positive COVID-19 laboratory test collected between November 9, 2020, and January 31, 2022, who met at least 1 emergency use authorization criterion for risk of a poor outcome. Exposure: Four nMAb products (bamlanivimab, bamlanivimab-etesevimab, casirivimab-imdevimab, and sotrovimab) administered in the outpatient setting. Main Outcomes and Measures: Clinical and SARS-CoV-2 genomic sequence data and propensity-adjusted marginal structural models were used to assess the association between treatment with nMAbs and 4 outcomes: all-cause emergency department (ED) visits, hospitalization, death, and a composite of hospitalization or death within 14 days and 30 days of the index date (defined as the date of the first positive COVID-19 test or the date of referral). Patient index dates were categorized into 4 variant epochs: pre-Delta (November 9, 2020, to June 30, 2021), Delta (July 1 to November 30, 2021), Delta and Omicron BA.1 (December 1 to 31, 2021), and Omicron BA.1 (January 1 to 31, 2022). Results: Among 167 183 patients, the mean (SD) age was 47.0 (18.5) years; 95 669 patients (57.2%) were female at birth, 139 379 (83.4%) were White, and 138 900 (83.1%) were non-Hispanic. A total of 25 241 patients received treatment with nMAbs. Treatment with nMAbs was associated with lower odds of ED visits within 14 days (odds ratio [OR], 0.76; 95% CI, 0.68-0.85), hospitalization within 14 days (OR, 0.52; 95% CI, 0.45-0.59), and death within 30 days (OR, 0.14; 95% CI, 0.10-0.20). The association between nMAbs and reduced risk of hospitalization was stronger in unvaccinated patients (14-day hospitalization: OR, 0.51; 95% CI, 0.44-0.59), and the associations with hospitalization and death were stronger in immunocompromised patients (hospitalization within 14 days: OR, 0.31 [95% CI, 0.24-0.41]; death within 30 days: OR, 0.13 [95% CI, 0.06-0.27]). The strength of associations of nMAbs increased incrementally among patients with a greater probability of poor outcomes; for example, the ORs for hospitalization within 14 days were 0.58 (95% CI, 0.48-0.72) among those in the third (moderate) risk stratum and 0.41 (95% CI, 0.32-0.53) among those in the fifth (highest) risk stratum. The association of nMAb treatment with reduced risk of hospitalizations within 14 days was strongest during the Delta variant epoch (OR, 0.37; 95% CI, 0.31-0.43) but not during the Omicron BA.1 epoch (OR, 1.29; 95% CI, 0.68-2.47). These findings were corroborated in the subset of patients with viral genomic data. Treatment with nMAbs was associated with a significant mortality benefit in all variant epochs (pre-Delta: OR, 0.16 [95% CI, 0.08-0.33]; Delta: OR, 0.14 [95% CI, 0.09-0.22]; Delta and Omicron BA.1: OR, 0.10 [95% CI, 0.03-0.35]; and Omicron BA.1: OR, 0.13 [95% CI, 0.02-0.93]). Potential adverse drug events were identified in 38 treated patients (0.2%). Conclusions and Relevance: In this study, nMAb treatment for COVID-19 was safe and associated with reductions in ED visits, hospitalization, and death, although it was not associated with reduced risk of hospitalization during the Omicron BA.1 epoch. These findings suggest that targeted risk stratification strategies may help optimize future nMAb treatment decisions.


Subject(s)
COVID-19 , Infant, Newborn , Humans , Female , Middle Aged , Male , SARS-CoV-2 , Retrospective Studies , Antibodies, Monoclonal
2.
Viruses ; 14(12)2022 12 12.
Article in English | MEDLINE | ID: covidwho-2163616

ABSTRACT

There is mounting evidence of SARS-CoV-2 spillover from humans into many domestic, companion, and wild animal species. Research indicates that humans have infected white-tailed deer, and that deer-to-deer transmission has occurred, indicating that deer could be a wildlife reservoir and a source of novel SARS-CoV-2 variants. We examined the hypothesis that the Omicron variant is actively and asymptomatically infecting the free-ranging deer of New York City. Between December 2021 and February 2022, 155 deer on Staten Island, New York, were anesthetized and examined for gross abnormalities and illnesses. Paired nasopharyngeal swabs and blood samples were collected and analyzed for the presence of SARS-CoV-2 RNA and antibodies. Of 135 serum samples, 19 (14.1%) indicated SARS-CoV-2 exposure, and 11 reacted most strongly to the wild-type B.1 lineage. Of the 71 swabs, 8 were positive for SARS-CoV-2 RNA (4 Omicron and 4 Delta). Two of the animals had active infections and robust neutralizing antibodies, revealing evidence of reinfection or early seroconversion in deer. Variants of concern continue to circulate among and may reinfect US deer populations, and establish enzootic transmission cycles in the wild: this warrants a coordinated One Health response, to proactively surveil, identify, and curtail variants of concern before they can spill back into humans.


Subject(s)
COVID-19 , Deer , Humans , Animals , New York City/epidemiology , RNA, Viral/genetics , SARS-CoV-2/genetics , COVID-19/epidemiology , COVID-19/veterinary , Animals, Wild
3.
Cell Host Microbe ; 30(9): 1242-1254.e6, 2022 09 14.
Article in English | MEDLINE | ID: covidwho-2035852

ABSTRACT

The worldwide spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has led to the repeated emergence of variants of concern. For the Omicron variant, sub-lineages BA.1 and BA.2, respectively, contain 33 and 29 nonsynonymous and indel spike protein mutations. These amino acid substitutions and indels are implicated in increased transmissibility and enhanced immune evasion. By reverting individual spike mutations of BA.1 or BA.2, we characterize the molecular effects of the Omicron spike mutations on expression, ACE2 receptor affinity, and neutralizing antibody recognition. We identified key mutations enabling escape from neutralizing antibodies at a variety of epitopes. Stabilizing mutations in the N-terminal and S2 domains of the spike protein can compensate for destabilizing mutations in the receptor binding domain, enabling the record number of mutations in Omicron. Our results provide a comprehensive account of the mutational effects in the Omicron spike protein and illustrate previously uncharacterized mechanisms of host evasion.


Subject(s)
COVID-19 , Spike Glycoprotein, Coronavirus , Angiotensin-Converting Enzyme 2/genetics , Antibodies, Neutralizing/genetics , Antibodies, Viral , Epitopes , Humans , Membrane Glycoproteins , Mutation , SARS-CoV-2/genetics , Spike Glycoprotein, Coronavirus/genetics , Viral Envelope Proteins
4.
Sci Rep ; 12(1): 12094, 2022 07 15.
Article in English | MEDLINE | ID: covidwho-1937445

ABSTRACT

The emergence of a novel pathogen in a susceptible population can cause rapid spread of infection. High prevalence of SARS-CoV-2 infection in white-tailed deer (Odocoileus virginianus) has been reported in multiple locations, likely resulting from several human-to-deer spillover events followed by deer-to-deer transmission. Knowledge of the risk and direction of SARS-CoV-2 transmission between humans and potential reservoir hosts is essential for effective disease control and prioritisation of interventions. Using genomic data, we reconstruct the transmission history of SARS-CoV-2 in humans and deer, estimate the case finding rate and attempt to infer relative rates of transmission between species. We found no evidence of direct or indirect transmission from deer to human. However, with an estimated case finding rate of only 4.2%, spillback to humans cannot be ruled out. The extensive transmission of SARS-CoV-2 within deer populations and the large number of unsampled cases highlights the need for active surveillance at the human-animal interface.


Subject(s)
COVID-19 , Deer , SARS-CoV-2 , Viral Zoonoses , Animals , COVID-19/epidemiology , COVID-19/prevention & control , COVID-19/transmission , COVID-19/veterinary , Deer/virology , Environmental Monitoring , Humans , Risk Assessment , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , Viral Zoonoses/epidemiology , Viral Zoonoses/transmission , Viral Zoonoses/virology
5.
Open forum infectious diseases ; 8(11), 2021.
Article in English | EuropePMC | ID: covidwho-1837213

ABSTRACT

Background Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) continues to spread globally and cause significant morbidity and mortality. Antispike protein monoclonal antibody (mAb) therapy has been shown to prevent progression to severe coronavirus disease 2019 (COVID-19). The objective of this study was to report the outcomes of high-risk, SARS-CoV-2-positive patients infused with 1 of the 3 mAb therapies available through Food and Drug Administration Emergency Use Authorization (EUA). Methods A total of 4328 SARS-CoV-2-positive patients who satisfied EUA criteria for eligibility for receiving mAb therapy were infused with bamlanivimab or the combination therapies bamlanivimab-etesevimab or casirivimab-imdevimab from November 22, 2020, to May 31, 2021, at 6 infusion clinics and multiple emergency departments within the 8 Houston Methodist Hospitals in Houston, Texas. The primary outcome of hospital admission within 14 and 28 days postinfusion was assessed relative to a propensity score–matched cohort, matched based on age, race/ethnicity, median income by zip code, body mass index, comorbidities, and positive polymerase chain reaction date. Secondary outcomes included intensive care unit admission and mortality. Results A total of 2879 infused patients and matched controls were included in the analysis, including 1718 patients infused with bamlanivimab, 346 patients infused with bamlanivimab-etesevimab, and 815 patients infused with casirivimab-imdevimab. Hospital admission and mortality rates were significantly decreased overall in mAb-infused patients relative to matched controls. Among the infused cohort, those who received casirivimab-imdevimab had a significantly decreased rate of admission relative to the other 2 mAb therapy groups (adjusted risk ratio,0.51;P=.001). Conclusions Treatment with bamlanivimab, bamlanivimab-etesevimab, or casirivimab-imdevimab significantly decreased the number of patients who progressed to severe COVID-19 disease and required hospitalization.

6.
Am J Pathol ; 192(4): 642-652, 2022 04.
Article in English | MEDLINE | ID: covidwho-1777930

ABSTRACT

Genetic variants of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) continue to dramatically alter the landscape of the coronavirus disease 2019 (COVID-19) pandemic. The recently described variant of concern designated Omicron (B.1.1.529) has rapidly spread worldwide and is now responsible for the majority of COVID-19 cases in many countries. Because Omicron was recognized recently, many knowledge gaps exist about its epidemiology, clinical severity, and disease course. A genome sequencing study of SARS-CoV-2 in the Houston Methodist health care system identified 4468 symptomatic patients with infections caused by Omicron from late November 2021 through January 5, 2022. Omicron rapidly increased in only 3 weeks to cause 90% of all new COVID-19 cases, and at the end of the study period caused 98% of new cases. Compared with patients infected with either Alpha or Delta variants in our health care system, Omicron patients were significantly younger, had significantly increased vaccine breakthrough rates, and were significantly less likely to be hospitalized. Omicron patients required less intense respiratory support and had a shorter length of hospital stay, consistent with on average decreased disease severity. Two patients with Omicron stealth sublineage BA.2 also were identified. The data document the unusually rapid spread and increased occurrence of COVID-19 caused by the Omicron variant in metropolitan Houston, Texas, and address the lack of information about disease character among US patients.


Subject(s)
COVID-19 , Vaccines , COVID-19/epidemiology , Hospitalization , Humans , SARS-CoV-2/genetics , Texas/epidemiology
7.
Proc Natl Acad Sci U S A ; 119(6)2022 02 08.
Article in English | MEDLINE | ID: covidwho-1655775

ABSTRACT

Many animal species are susceptible to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and could act as reservoirs; however, transmission in free-living animals has not been documented. White-tailed deer, the predominant cervid in North America, are susceptible to SARS-CoV-2 infection, and experimentally infected fawns can transmit the virus. To test the hypothesis that SARS-CoV-2 is circulating in deer, 283 retropharyngeal lymph node (RPLN) samples collected from 151 free-living and 132 captive deer in Iowa from April 2020 through January of 2021 were assayed for the presence of SARS-CoV-2 RNA. Ninety-four of the 283 (33.2%) deer samples were positive for SARS-CoV-2 RNA as assessed by RT-PCR. Notably, following the November 2020 peak of human cases in Iowa, and coinciding with the onset of winter and the peak deer hunting season, SARS-CoV-2 RNA was detected in 80 of 97 (82.5%) RPLN samples collected over a 7-wk period. Whole genome sequencing of all 94 positive RPLN samples identified 12 SARS-CoV-2 lineages, with B.1.2 (n = 51; 54.5%) and B.1.311 (n = 19; 20%) accounting for ∼75% of all samples. The geographic distribution and nesting of clusters of deer and human lineages strongly suggest multiple human-to-deer transmission events followed by subsequent deer-to-deer spread. These discoveries have important implications for the long-term persistence of the SARS-CoV-2 pandemic. Our findings highlight an urgent need for a robust and proactive "One Health" approach to obtain enhanced understanding of the ecology, molecular evolution, and dissemination of SARS-CoV-2.


Subject(s)
COVID-19/transmission , Deer/virology , SARS-CoV-2/isolation & purification , Zoonoses/virology , Animals , COVID-19/virology , Disease Reservoirs/virology , Humans , SARS-CoV-2/genetics
8.
Microbiol Spectr ; 9(3): e0180321, 2021 12 22.
Article in English | MEDLINE | ID: covidwho-1561786

ABSTRACT

The ARTIC Network provides a common resource of PCR primer sequences and recommendations for amplifying SARS-CoV-2 genomes. The initial tiling strategy was developed with the reference genome Wuhan-01, and subsequent iterations have addressed areas of low amplification and sequence drop out. Recently, a new version (V4) was released, based on new variant genome sequences, in response to the realization that some V3 primers were located in regions with key mutations. Herein, we compare the performance of the ARTIC V3 and V4 primer sets with a matched set of 663 SARS-CoV-2 clinical samples sequenced with an Illumina NovaSeq 6000 instrument. We observe general improvements in sequencing depth and quality, and improved resolution of the SNP causing the D950N variation in the spike protein. Importantly, we also find nearly universal presence of spike protein substitution G142D in Delta-lineage samples. Due to the prior release and widespread use of the ARTIC V3 primers during the initial surge of the Delta variant, it is likely that the G142D amino acid substitution is substantially underrepresented among early Delta variant genomes deposited in public repositories. In addition to the improved performance of the ARTIC V4 primer set, this study also illustrates the importance of the primer scheme in downstream analyses. IMPORTANCE ARTIC Network primers are commonly used by laboratories worldwide to amplify and sequence SARS-CoV-2 present in clinical samples. As new variants have evolved and spread, it was found that the V3 primer set poorly amplified several key mutations. In this report, we compare the results of sequencing a matched set of samples with the V3 and V4 primer sets. We find that adoption of the ARTIC V4 primer set is critical for accurate sequencing of the SARS-CoV-2 spike region. The absence of metadata describing the primer scheme used will negatively impact the downstream use of publicly available SARS-Cov-2 sequencing reads and assembled genomes.


Subject(s)
Amino Acid Substitution , COVID-19/virology , SARS-CoV-2/classification , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , Spike Glycoprotein, Coronavirus/genetics , Base Sequence , Genome, Viral , Humans , Mutation , Whole Genome Sequencing
9.
Am J Pathol ; 192(2): 320-331, 2022 02.
Article in English | MEDLINE | ID: covidwho-1509508

ABSTRACT

Genetic variants of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have repeatedly altered the course of the coronavirus disease 2019 (COVID-19) pandemic. Delta variants are now the focus of intense international attention because they are causing widespread COVID-19 globally and are associated with vaccine breakthrough cases. We sequenced 16,965 SARS-CoV-2 genomes from samples acquired March 15, 2021, through September 20, 2021, in the Houston Methodist hospital system. This sample represents 91% of all Methodist system COVID-19 patients during the study period. Delta variants increased rapidly from late April onward to cause 99.9% of all COVID-19 cases and spread throughout the Houston metroplex. Compared with all other variants combined, Delta caused a significantly higher rate of vaccine breakthrough cases (23.7% for Delta compared with 6.6% for all other variants combined). Importantly, significantly fewer fully vaccinated individuals required hospitalization. Vaccine breakthrough cases caused by Delta had a low median PCR cycle threshold value (a proxy for high virus load). This value was similar to the median cycle threshold value for unvaccinated patients with COVID-19 caused by Delta variants, suggesting that fully vaccinated individuals can transmit SARS-CoV-2 to others. Patients infected with Alpha and Delta variants had several significant differences. The integrated analysis indicates that vaccines used in the United States are highly effective in decreasing severe COVID-19, hospitalizations, and deaths.


Subject(s)
COVID-19/virology , SARS-CoV-2 , Adult , COVID-19 Vaccines , Female , Humans , Male , Middle Aged , Texas
10.
Am J Pathol ; 191(10): 1754-1773, 2021 10.
Article in English | MEDLINE | ID: covidwho-1486232

ABSTRACT

Certain genetic variants of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are of substantial concern because they may be more transmissible or detrimentally alter the pandemic course and disease features in individual patients. SARS-CoV-2 genome sequences from 12,476 patients in the Houston Methodist health care system diagnosed from January 1 through May 31, 2021 are reported here. Prevalence of the B.1.1.7 (Alpha) variant increased rapidly and caused 63% to 90% of new cases in the latter half of May. Eleven B.1.1.7 genomes had an E484K replacement in spike protein, a change also identified in other SARS-CoV-2 lineages. Compared with non-B.1.1.7-infected patients, individuals with B.1.1.7 had a significantly lower cycle threshold (a proxy for higher virus load) and significantly higher hospitalization rate. Other variants [eg, B.1.429 and B.1.427 (Epsilon), P.1 (Gamma), P.2 (Zeta), and R.1] also increased rapidly, although the magnitude was less than that in B.1.1.7. Twenty-two patients infected with B.1.617.1 (Kappa) or B.1.617.2 (Delta) variants had a high rate of hospitalization. Breakthrough cases (n = 207) in fully vaccinated patients were caused by a heterogeneous array of virus genotypes, including many not currently designated variants of interest or concern. In the aggregate, this study delineates the trajectory of SARS-CoV-2 variants circulating in a major metropolitan area, documents B.1.1.7 as the major cause of new cases in Houston, TX, and heralds the arrival of B.1.617 variants in the metroplex.


Subject(s)
COVID-19/epidemiology , Genome, Viral , Mutation , SARS-CoV-2/genetics , COVID-19/genetics , COVID-19/transmission , COVID-19/virology , Female , Humans , Male , Middle Aged , SARS-CoV-2/isolation & purification , Texas/epidemiology
11.
Mayo Clin Proc ; 96(5): 1262-1275, 2021 05.
Article in English | MEDLINE | ID: covidwho-1219471

ABSTRACT

To determine the effect of COVID-19 convalescent plasma on mortality, we aggregated patient outcome data from 10 randomized clinical trials, 20 matched control studies, 2 dose-response studies, and 96 case reports or case series. Studies published between January 1, 2020, and January 16, 2021, were identified through a systematic search of online PubMed and MEDLINE databases. Random effects analyses of randomized clinical trials and matched control data demonstrated that patients with COVID-19 transfused with convalescent plasma exhibited a lower mortality rate compared with patients receiving standard treatments. Additional analyses showed that early transfusion (within 3 days of hospital admission) of higher titer plasma is associated with lower patient mortality. These data provide evidence favoring the efficacy of human convalescent plasma as a therapeutic agent in hospitalized patients with COVID-19.


Subject(s)
COVID-19/therapy , COVID-19/mortality , Humans , Immunization, Passive/methods , Mortality , SARS-CoV-2/immunology , Time-to-Treatment , COVID-19 Serotherapy
12.
Am J Pathol ; 191(6): 983-992, 2021 06.
Article in English | MEDLINE | ID: covidwho-1157092

ABSTRACT

Since the beginning of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic, there has been international concern about the emergence of virus variants with mutations that increase transmissibility, enhance escape from the human immune response, or otherwise alter biologically important phenotypes. In late 2020, several variants of concern emerged globally, including the UK variant (B.1.1.7), the South Africa variant (B.1.351), Brazil variants (P.1 and P.2), and two related California variants of interest (B.1.429 and B.1.427). These variants are believed to have enhanced transmissibility. For the South Africa and Brazil variants, there is evidence that mutations in spike protein permit it to escape from some vaccines and therapeutic monoclonal antibodies. On the basis of our extensive genome sequencing program involving 20,453 coronavirus disease 2019 patient samples collected from March 2020 to February 2021, we report identification of all six of these SARS-CoV-2 variants among Houston Methodist Hospital (Houston, TX) patients residing in the greater metropolitan area. Although these variants are currently at relatively low frequency (aggregate of 1.1%) in the population, they are geographically widespread. Houston is the first city in the United States in which active circulation of all six current variants of concern has been documented by genome sequencing. As vaccine deployment accelerates, increased genomic surveillance of SARS-CoV-2 is essential to understanding the presence, frequency, and medical impact of consequential variants and their patterns and trajectory of dissemination.


Subject(s)
COVID-19 , Mutation , Pandemics , SARS-CoV-2/genetics , COVID-19/epidemiology , COVID-19/genetics , COVID-19/transmission , Female , Humans , Male , SARS-CoV-2/isolation & purification , Texas/epidemiology
13.
Commun Biol ; 4(1): 267, 2021 02 24.
Article in English | MEDLINE | ID: covidwho-1101684

ABSTRACT

Millions of individuals who have recovered from SARS-CoV-2 infection may be eligible to participate in convalescent plasma donor programs, yet the optimal window for donating high neutralizing titer convalescent plasma for COVID-19 immunotherapy remains unknown. Here we studied the response trajectories of antibodies directed to the SARS-CoV-2 surface spike glycoprotein and in vitro SARS-CoV-2 live virus neutralizing titers (VN) in 175 convalescent donors longitudinally sampled for up to 142 days post onset of symptoms (DPO). We observed robust IgM, IgG, and viral neutralization responses to SARS-CoV-2 that persist, in the aggregate, for at least 100 DPO. However, there is a notable decline in VN titers ≥160 for convalescent plasma therapy, starting 60 DPO. The results also show that individuals 30 years of age or younger have significantly lower VN, IgG and IgM antibody titers than those in the older age groups; and individuals with greater disease severity also have significantly higher IgM and IgG antibody titers. Taken together, these findings define the optimal window for donating convalescent plasma useful for immunotherapy of COVID-19 patients and reveal important predictors of an ideal plasma donor.


Subject(s)
Antibodies, Neutralizing/blood , Antibodies, Viral/blood , Blood Donors , COVID-19/immunology , SARS-CoV-2/immunology , Adult , Age Factors , Aged , Antibodies, Neutralizing/immunology , Antibodies, Viral/immunology , COVID-19/blood , COVID-19/therapy , Female , Humans , Immunoglobulin G/blood , Immunoglobulin G/immunology , Immunoglobulin M/blood , Immunoglobulin M/immunology , Longitudinal Studies , Male , Middle Aged , Severity of Illness Index , Time Factors , Young Adult
14.
J Clin Invest ; 130(12): 6728-6738, 2020 12 01.
Article in English | MEDLINE | ID: covidwho-972513

ABSTRACT

The newly emerged severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) highlights the urgent need for assays that detect protective levels of neutralizing antibodies. We studied the relationship among anti-spike ectodomain (anti-ECD), anti-receptor-binding domain (anti-RBD) IgG titers, and SARS-CoV-2 virus neutralization (VN) titers generated by 2 in vitro assays using convalescent plasma samples from 68 patients with COVID-19. We report a strong positive correlation between both plasma anti-RBD and anti-ECD IgG titers and in vitro VN titers. The probability of a VN titer of ≥160, the FDA-recommended level for convalescent plasma used for COVID-19 treatment, was ≥80% when anti-RBD or anti-ECD titers were ≥1:1350. Of all donors, 37% lacked VN titers of ≥160. Dyspnea, hospitalization, and disease severity were significantly associated with higher VN titer. Frequent donation of convalescent plasma did not significantly decrease VN or IgG titers. Analysis of 2814 asymptomatic adults found 73 individuals with anti-ECD IgG titers of ≥1:50 and strong positive correlation with anti-RBD and VN titers. Fourteen of these individuals had VN titers of ≥1:160, and all of them had anti-RBD titers of ≥1:1350. We conclude that anti-RBD or anti-ECD IgG titers can serve as a surrogate for VN titers to identify suitable plasma donors. Plasma anti-RBD or anti-ECD titers of ≥1:1350 may provide critical information about protection against COVID-19 disease.


Subject(s)
Antibodies, Neutralizing , Antibodies, Viral , COVID-19/therapy , Immunoglobulin G , SARS-CoV-2 , Adolescent , Adult , Aged , Antibodies, Neutralizing/administration & dosage , Antibodies, Neutralizing/blood , Antibodies, Viral/administration & dosage , Antibodies, Viral/blood , Female , Humans , Immunization, Passive , Immunoglobulin G/administration & dosage , Immunoglobulin G/blood , Male , Middle Aged , COVID-19 Serotherapy
15.
Am J Pathol ; 191(1): 90-107, 2021 01.
Article in English | MEDLINE | ID: covidwho-938719

ABSTRACT

Coronavirus disease 2019 (COVID-19) convalescent plasma has emerged as a promising therapy and has been granted Emergency Use Authorization by the US Food and Drug Administration for hospitalized COVID-19 patients. We recently reported results from interim analysis of a propensity score-matched study suggesting that early treatment of COVID-19 patients with convalescent plasma containing high-titer anti-spike protein receptor binding domain (RBD) IgG significantly decreases mortality. We herein present results from a 60-day follow-up of a cohort of 351 transfused hospitalized patients. Prospective determination of enzyme-linked immunosorbent assay anti-RBD IgG titer facilitated selection and transfusion of the highest titer units available. Retrospective analysis by the Ortho VITROS IgG assay revealed a median signal/cutoff ratio of 24.0 for transfused units, a value far exceeding the recent US Food and Drug Administration-required cutoff of 12.0 for designation of high-titer convalescent plasma. With respect to altering mortality, our analysis identified an optimal window of 44 hours after hospitalization for transfusing COVID-19 patients with high-titer convalescent plasma. In the aggregate, the analysis confirms and extends our previous preliminary finding that transfusion of COVID-19 patients soon after hospitalization with high-titer anti-spike protein RBD IgG present in convalescent plasma significantly reduces mortality.


Subject(s)
COVID-19/mortality , COVID-19/therapy , Immunoglobulin G/immunology , Spike Glycoprotein, Coronavirus/immunology , Adult , Aged , Aged, 80 and over , Antibodies, Neutralizing/immunology , Antibodies, Viral/immunology , Female , Follow-Up Studies , Hospitalization , Humans , Immunization, Passive , Kaplan-Meier Estimate , Linear Models , Male , Middle Aged , Propensity Score , Proportional Hazards Models , Retrospective Studies , Risk , SARS-CoV-2 , Treatment Outcome , COVID-19 Serotherapy
16.
Am J Pathol ; 190(11): 2290-2303, 2020 11.
Article in English | MEDLINE | ID: covidwho-877760

ABSTRACT

Coronavirus disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2, has spread globally, and proven treatments are limited. Transfusion of convalescent plasma collected from donors who have recovered from COVID-19 is among many approaches being studied as potentially efficacious therapy. We are conducting a prospective, propensity score-matched study assessing the efficacy of COVID-19 convalescent plasma transfusion versus standard of care as treatment for severe and/or critical COVID-19. We present herein the results of an interim analysis of 316 patients enrolled at Houston Methodist hospitals from March 28 to July 6, 2020. Of the 316 transfused patients, 136 met a 28-day outcome and were matched to 251 non-transfused control COVID-19 patients. Matching criteria included age, sex, body mass index, comorbidities, and baseline ventilation requirement 48 hours from admission, and in a second matching analysis, ventilation status at day 0. Variability in the timing of transfusion relative to admission and titer of antibodies of plasma transfused allowed for analysis in specific matched cohorts. The analysis showed a significant reduction (P = 0.047) in mortality within 28 days, specifically in patients transfused within 72 hours of admission with plasma with an anti-spike protein receptor binding domain titer of ≥1:1350. These data suggest that treatment of COVID-19 with high anti-receptor binding domain IgG titer convalescent plasma is efficacious in early-disease patients.


Subject(s)
Betacoronavirus/pathogenicity , Coronavirus Infections/mortality , Plasma/immunology , Pneumonia, Viral/mortality , Adult , Aged , Aged, 80 and over , Blood Component Transfusion/methods , COVID-19 , Coronavirus Infections/diagnosis , Coronavirus Infections/therapy , Coronavirus Infections/virology , Female , Humans , Immunization, Passive/mortality , Male , Middle Aged , Pandemics , Plasma/virology , Pneumonia, Viral/diagnosis , Pneumonia, Viral/virology , Prospective Studies , SARS-CoV-2 , COVID-19 Serotherapy
17.
Am J Pathol ; 190(8): 1680-1690, 2020 08.
Article in English | MEDLINE | ID: covidwho-677458

ABSTRACT

Coronavirus disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2, has spread globally, and no proven treatments are available. Convalescent plasma therapy has been used with varying degrees of success to treat severe microbial infections for >100 years. Patients (n = 25) with severe and/or life-threatening COVID-19 disease were enrolled at the Houston Methodist hospitals from March 28, 2020, to April 14, 2020. Patients were transfused with convalescent plasma, obtained from donors with confirmed severe acute respiratory syndrome coronavirus 2 infection who had recovered. The primary study outcome was safety, and the secondary outcome was clinical status at day 14 after transfusion. Clinical improvement was assessed on the basis of a modified World Health Organization six-point ordinal scale and laboratory parameters. Viral genome sequencing was performed on donor and recipient strains. At day 7 after transfusion with convalescent plasma, nine patients had at least a one-point improvement in clinical scale, and seven of those were discharged. By day 14 after transfusion, 19 (76%) patients had at least a one-point improvement in clinical status, and 11 were discharged. No adverse events as a result of plasma transfusion were observed. Whole genome sequencing data did not identify a strain genotype-disease severity correlation. The data indicate that administration of convalescent plasma is a safe treatment option for those with severe COVID-19 disease.


Subject(s)
Coronavirus Infections/therapy , Pneumonia, Viral/therapy , Adult , Aged , Betacoronavirus/genetics , COVID-19 , Female , Humans , Immunization, Passive , Investigational New Drug Application , Male , Middle Aged , Pandemics , SARS-CoV-2 , Texas , Whole Genome Sequencing , Young Adult , COVID-19 Serotherapy
SELECTION OF CITATIONS
SEARCH DETAIL